CONCRETE MASONRY COMPRESSIVE STRENGTH USING THE UNIT STRENGTH METHOD FOR GROUTED MASONRY

Loading...
Thumbnail Image

Citation for Previous Publication

Link to Related Item

Abstract

Description

The objective of the analysis summarized in this report is to re-establish the correlation between unit strength and prism strength using more recent test results. These correlations were examined using a large database of available test results of prism testing conducted in North America. The analysis presented in this report is intended to be complementary to a report based on hollow masonry construction, also prepared in the University of Alberta (Gayed, 2011), and parallels a similar research project performed by the National Concrete Masonry Association in the United States (NCMA, 2012).