Abstract

Ductile steel plate shear walls are an established lateral load resisting system. Past research indicates that cold-rolled infill panels less than 1 mm in thickness present one solution to an overstrength problem arising from selecting an infill panel thickness based on ease of welding and handling. This research program examines several possible welding procedures and joint geometry to connect the thin infill panel to the thick boundary elements.

Primary welding parameters include short-circuiting gas metal arc welding process, electrode and shielding gas selection, heat input, and use of a chill strip. Four configurations of the infill panel-to-boundary element joint and two configurations of a lap splice joint between two sheets of thin steel in the infill panel were tested in monotonic tension and cyclic tension-compression. A quasi-static cyclic test of a single-storey moment resisting frame steel plate shear wall validated the use of one welding procedure and joint geometry.

Item Type

http://purl.org/coar/resource_type/c_46ec

Alternative

License

Other License Text / Link

This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.

Language

en

Location

Time Period

Source